These devices do not run Ubiquiti AirOS. Rename the partition to the
name used by other UniFi devices with vendor dualboot support.
Signed-off-by: David Bauer <mail@david-bauer.net>
The NanoPi R2S does not have a board specific MAC address written inside
e.g. an EEPROM, hence why it is randomly generated on first boot.
The issue with that however is the lack of a driver for the PRNG.
It often results to the same MAC address used on multiple boards by
default, as urngd is not active at this early stage resulting in low
available entropy.
There is however a semi-unique identifier available to us, which is the
CID of the used SD card. It is unique to each SD card, hence we can use
it to generate the MAC address used for LAN and WAN.
Signed-off-by: David Bauer <mail@david-bauer.net>
The removed config symbols are already enabled by the generic kernel
configuration (or by default), while the added ones are forcefully
enabled by the specific architecture.
Signed-off-by: Rui Salvaterra <rsalvaterra@gmail.com>
The USB port definition is only needed when it is linked to a USB
LED. Since there is none for this device, we might as well remove
the port definition.
Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
CPU: Atheros AR9342 rev 3 SoC
RAM: 64 MB DDR2
Flash: 16 MB NOR SPI
WLAN 2.4GHz: Atheros AR9342 v3 (ath9k)
WLAN 5.0GHz: QCA988X
Ports: 1x GbE
Flashing procedure is identical to other ubnt devices.
https://openwrt.org/toh/ubiquiti/common
Flashing through factory firmware
1. Ensure firmware version v8.7.0 is installed.
Up/downgrade to this exact version.
2. Patch fwupdate.real binary using
`hexdump -Cv /bin/ubntbox | sed 's/14 40 fe 27/00 00 00 00/g' | \
hexdump -R > /tmp/fwupdate.real`
3. Make the patched fwupdate.real binary executable using
`chmod +x /tmp/fwupdate.real`
4. Copy the squashfs factory image to /tmp on the device
5. Flash OpenWrt using `/tmp/fwupdate.real -m <squashfs-factory image>`
6. Wait for the device to reboot
(copied from Ubiquiti NanoBeam AC and modified)
Flashing from serial console
1. Connect serial console (115200 baud)
2. Connect ethernet to a network with a TFTP server, through a
passive PoE injector.
3. Press a key to obtain a u-boot prompt
4. Set your TFTP server's ip address, with:
setenv serverip <tftp-server-address>
5. Set the Bullet AC's ip address, with:
setenv ipaddr <bullet-ac-address>
6. Set the boot file, with:
setenv bootfile <name-of-initramfs-binary-on-tftp-server>
7. Fetch the binary with tftp:
tftpboot
8. Boot the initramfs binary:
bootm
9. From the initramfs, fetch the sysupgrade binary, and flash it with
sysupgrade.
The Bullet AC is identified as a 2WA board by Ubiquiti. As such, the UBNT_TYPE
must match from the "Flashing through factory firmware" install instructions
to work.
Phy0 is QCA988X which can tune either band (2.4 or 5GHz). Phy1 is AR9342,
on which 5GHz is disabled. It isn't currently known whether phy1 is
routed to the N connector at all.
Signed-off-by: Russell Senior <russell@personaltelco.net>
The following four led triggers are enabled in generic config.
* kmod-ledtrig-default-on
* kmod-ledtrig-heartbeat
* kmod-ledtrig-netdev
* kmod-ledtrig-timer
Drop the packages and remove them from DEVICE_PACKAGES.
There's no other package depending on them in this repo.
Signed-off-by: Sungbo Eo <mans0n@gorani.run>
Those targets have already enabled some other LED triggers, so enabling
a few more won't be a big problem.
Signed-off-by: Sungbo Eo <mans0n@gorani.run>
The heartbeat trigger is used by luci-mod-system, which is installed
as a part of the standard luci package set. It seems the LED trigger
will be required quite often, so let's enable it by default.
This increases uncompressed kernel size by about 100 bytes on ath79/generic.
Signed-off-by: Sungbo Eo <mans0n@gorani.run>
CONFIG_THERMAL option was changed to boolean in upstream linux commit
554b3529fe01 ("thermal/drivers/core: Remove the module Kconfig's option").
Switch it to 'y' and remove FILES and AUTOLOAD for non-existant module file.
And update the descripton text for the package as in upstream linux commit
eb8504620381 ("thermal: Rephrase the Kconfig text for thermal").
Signed-off-by: Sungbo Eo <mans0n@gorani.run>
All modification made by update_kernel.sh in a fresh clone without
existing toolchains.
Build system: x86_64
Build-tested: ipq806x/R7800, bcm27xx/bcm2711
Run-tested: ipq806x/R7800
No dmesg regressions, everything functional
Signed-off-by: John Audia <graysky@archlinux.us>
Tested-by: Curtis Deptuck <curtdept@me.com> [x86/64]
This allows libnetfilter_queue to access connection tracking information
by requesting NFQA_CFG_F_CONNTRACK. Connection tracking information is
provided in the NFQA_CT attribute.
CONFIG_NETFILTER_NETLINK_GLUE_CT enables the interaction between
nf_queue and nf_conntrack_netlink. Without this option, trying to access
connection tracking information results in "Operation not supported".
Signed-off-by: Etan Kissling <etan_kissling@apple.com>
BCM4906, BCM4908 and BCM49408 are SoCs with 64 bit ARMv8 B53 CPUs.
Upstream Linux is slowly getting support for that SoCs family so it
makes sense to add target for it.
This prepares initial support for:
1. Asus GT-AC5300
BCM4908 based device (4 CPUs) with 1024 MiB RAM, NAND, 8 LAN ports.
2. Netgear R8000P
BCM4906 based device (2 CPUs) with 512 MiB RAM, NAND, 4 LAN ports.
Flashing info will come later as we learn how to generate proper images.
It isn't usable yet (it only produces a bootable kernel) so "source-only"
is used.
Signed-off-by: Rafał Miłecki <rafal@milecki.pl>
Enable the ability to use segment routing based on IPv6. It allows the
packet to specify a path that the packet should take through the
network.
Lwtunnel allow an easy encapsulation of a package. You can just install
ip-full package and use it:
ip -6 route add 2003::/64 dev eth0 encap seg6 mode encap \
segs 2001::1,2002::2
An IPv6 package looks like this:
[IPv6 HDR][IPv6 RH][IPv6 HDR][Data...]
Netifd support:
https://git.openwrt.org/?p=project/netifd.git;
a=commit;h=458b1a7e9473c150a40cae5d8be174f4bb03bd39
Increases imagesize by 24.125 KiB. Therefore, only enable for devices
with enough flash.
Signed-off-by: Nick Hainke <vincent@systemli.org>
When compiling with CONFIG_ALL_KMODS enabled, compilation might stall
due to unset rockchip-specific config symbols. Disable these to avoid
stalling this step.
Signed-off-by: David Bauer <mail@david-bauer.net>
The flash capacity is divided in two flash chips and currently only
first is used. Increase available space for OpenWrt by additional 16 MiB
using mtd-concat driver. Because U-Boot might not be able to load kernel
image spanned through two flash chips, the size of kernel is limited
to space available on first first chip.
Cc: Vladimir Georgievsky <vladimir.georgievsky@yahoo.com>
Signed-off-by: Tomasz Maciej Nowak <tmn505@gmail.com>
This device has (almost?) identical hardware to the F9J1108 v2 but uses
a different firmware magic and model number.
Specifications:
SoC: QCA9558
CPU: 720 MHz
Flash: 16 MiB NOR
RAM: 128 MiB
WiFi 2.4 GHz: QCA9558-AT4A 3x3 MIMO 802.11b/g/n
WiFi 5 GHz: QCA9880-2R4E 3x3 MIMO 802.11a/n/ac
Ethernet: 4x LAN and 1x WAN (all 1Gbit/s ports)
USB: 1 x USB 2.0 (lower), 1 x USB 3.0 (upper)
MAC addresses based on OEM firmware:
Interface Address Location
--------- ------- --------
lan *:5A sometimes in 0x6
wan *:5B 0x0
2.4Ghz *:5A 0x1002
5Ghz As per mini PCIe EEPROM
Flashing instructions:
The factory.bin can be flashed via the Belkin web UI or via the uboot
HTTP upgrade page (which is by default listening on 192.168.2.1). Once
the factory.bin has been written, sysupgrade.bin will work as usual.
Signed-off-by: Martin Blumenstingl <martin.blumenstingl@googlemail.com>
This moves some of the Engenius boards from generic to tiny:
- EAP350 v1
- ECB350 v1
- ENH202 v1
For these, factory.bin builds are already failing on master
branch because of the unique situation for these boards:
- 8 MB flash
- an extra "failsafe" image for recovery
- TFTP does not work (barely possible with 600 MTU)
- bootloader loads image from a longer flash offset
- 1 eraseblock each needed for OKLI kernel loader and fake rootfs
- using mtd-concat to make use of remaining space...
The manual alternative would be removing the failsafe partition.
However this comes with the risk of extremely difficult recovery
if a flash ever fails because TFTP on the bootloader is bugged.
Signed-off-by: Michael Pratt <mcpratt@pm.me>
[improve commit message]
Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
Belkin F9J1108 v2 and F9K1115 v2 are (seemingly) identical hardware
with different model numbers. Extract all non-device specific code to a
common .dtsi so it can be re-used when adding support for the
F9K1115 v2.
Similar to the .dtsi most of the image building recipe code can be
re-used. Move everything except the device model, edimax header magic
and edimax header model into a shared build recipe.
Signed-off-by: Martin Blumenstingl <martin.blumenstingl@googlemail.com>
[drop duplicate TARGET_DEVICES, add EDIMAX_* to DEVICE_VARS, edit title]
Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
FCC ID: U2M-EAP350
Engenius EAP350 is a wireless access point with 1 gigabit PoE ethernet port,
2.4 GHz wireless, external ethernet switch, and 2 internal antennas.
Specification:
- AR7242 SOC
- AR9283 WLAN (2.4 GHz, 2x2, PCIe on-board)
- AR8035-A switch (GbE with 802.3af PoE)
- 40 MHz reference clock
- 8 MB FLASH MX25L6406E
- 32 MB RAM EM6AA160TSA-5G
- UART at J2 (populated)
- 3 LEDs, 1 button (power, eth, 2.4 GHz) (reset)
- 2 internal antennas
MAC addresses:
MAC address is labeled as "MAC"
Only 1 address on label and in flash
The OEM software reports these MACs for the ifconfig
eth0 MAC *:0c art 0x0
phy0 --- *:0d ---
Installation:
2 ways to flash factory.bin from OEM:
- if you get Failsafe Mode from failed flash:
only use it to flash Original firmware from Engenius
or risk kernel loop or halt which requires serial cable
Method 1: Firmware upgrade page:
OEM webpage at 192.168.10.1
username and password "admin"
Navigate to "Upgrade Firmware" page from left pane
Click Browse and select the factory.bin image
Upload and verify checksum
Click Continue to confirm and wait 3 minutes
Method 2: Serial to load Failsafe webpage:
After connecting to serial console and rebooting...
Interrupt uboot with any key pressed rapidly
execute `run failsafe_boot` OR `bootm 0x9f670000`
wait a minute
connect to ethernet and navigate to
"192.168.1.1/index.htm"
Select the factory.bin image and upload
wait about 3 minutes
Return to OEM:
If you have a serial cable, see Serial Failsafe instructions
otherwise, uboot-env can be used to make uboot load the failsafe image
*DISCLAIMER*
The Failsafe image is unique to Engenius boards.
If the failsafe image is missing or damaged this will not work
DO NOT downgrade to ar71xx this way, it can cause kernel loop or halt
ssh into openwrt and run
`fw_setenv rootfs_checksum 0`
reboot, wait 3 minutes
connect to ethernet and navigate to 192.168.1.1/index.htm
select OEM firmware image from Engenius and click upgrade
Format of OEM firmware image:
The OEM software of EAP350 is a heavily modified version
of Openwrt Kamikaze. One of the many modifications
is to the sysupgrade program. Image verification is performed
simply by the successful ungzip and untar of the supplied file
and name check and header verification of the resulting contents.
To form a factory.bin that is accepted by OEM Openwrt build,
the kernel and rootfs must have specific names...
openwrt-senao-eap350-uImage-lzma.bin
openwrt-senao-eap350-root.squashfs
and begin with the respective headers (uImage, squashfs).
Then the files must be tarballed and gzipped.
The resulting binary is actually a tar.gz file in disguise.
This can be verified by using binwalk on the OEM firmware images,
ungzipping then untaring.
The OEM upgrade script is at /etc/fwupgrade.sh
Later models in the EAP series likely have a different platform
and the upgrade and image verification process differs.
OKLI kernel loader is required because the OEM software
expects the kernel to be no greater than 1024k
and the factory.bin upgrade procedure would
overwrite part of the kernel when writing rootfs.
Note on PLL-data cells:
The default PLL register values will not work
because of the external AR8035-A switch between
the SOC and the ethernet PHY chips.
For AR724x series, the PLL register for GMAC0
can be seen in the DTSI as 0x2c.
Therefore the PLL register can be read from uboot
for each link speed after attempting tftpboot
or another network action using that link speed
with `md 0x1805002c 1`.
uboot did not have a good value for 1 GBps
so it was taken from other similar DTS file.
Tested from master, all link speeds functional
Signed-off-by: Michael Pratt <mcpratt@pm.me>
FCC ID: A8J-EAP600
Engenius EAP600 is a wireless access point with 1 gigabit ethernet port,
dual-band wireless, external ethernet switch, 4 internal antennas
and 802.3af PoE.
Specification:
- AR9344 SOC (5 GHz, 2x2, WMAC)
- AR9382 WLAN (2.4 GHz, 2x2, PCIe on-board)
- AR8035-A switch (GbE with 802.3af PoE)
- 40 MHz reference clock
- 16 MB FLASH MX25L12845EMI-10G
- 2x 64 MB RAM NT5TU32M16DG
- UART at H1 (populated)
- 5 LEDs, 1 button (power, eth, 2.4 GHz, 5 GHz, wps) (reset)
- 4 internal antennas
MAC addresses:
MAC addresses are labeled MAC1 and MAC2
The MAC address in flash is not on the label
The OEM software reports these MACs for the ifconfig
eth0 MAC 1 *:5e ---
phy1 MAC 2 *:5f --- (2.4 GHz)
phy0 ----- *:60 art 0x0 (5 GHz)
Installation:
2 ways to flash factory.bin from OEM:
- if you get Failsafe Mode from failed flash:
only use it to flash Original firmware from Engenius
or risk kernel loop or halt which requires serial cable
Method 1: Firmware upgrade page:
OEM webpage at 192.168.1.1
username and password "admin"
Navigate to "Upgrade Firmware" page from left pane
Click Browse and select the factory.bin image
Upload and verify checksum
Click Continue to confirm and wait 3 minutes
Method 2: Serial to load Failsafe webpage:
After connecting to serial console and rebooting...
Interrupt uboot with any key pressed rapidly
execute `run failsafe_boot` OR `bootm 0x9fdf0000`
wait a minute
connect to ethernet and navigate to
"192.168.1.1/index.htm"
Select the factory.bin image and upload
wait about 3 minutes
Return to OEM:
If you have a serial cable, see Serial Failsafe instructions
otherwise, uboot-env can be used to make uboot load the failsafe image
*DISCLAIMER*
The Failsafe image is unique to Engenius boards.
If the failsafe image is missing or damaged this will not work
DO NOT downgrade to ar71xx this way, it can cause kernel loop or halt
ssh into openwrt and run
`fw_setenv rootfs_checksum 0`
reboot, wait 3 minutes
connect to ethernet and navigate to 192.168.1.1/index.htm
select OEM firmware image from Engenius and click upgrade
Format of OEM firmware image:
The OEM software of EAP600 is a heavily modified version
of Openwrt Kamikaze. One of the many modifications
is to the sysupgrade program. Image verification is performed
simply by the successful ungzip and untar of the supplied file
and name check and header verification of the resulting contents.
To form a factory.bin that is accepted by OEM Openwrt build,
the kernel and rootfs must have specific names...
openwrt-senao-eap600-uImage-lzma.bin
openwrt-senao-eap600-root.squashfs
and begin with the respective headers (uImage, squashfs).
Then the files must be tarballed and gzipped.
The resulting binary is actually a tar.gz file in disguise.
This can be verified by using binwalk on the OEM firmware images,
ungzipping then untaring.
The OEM upgrade script is at /etc/fwupgrade.sh
Later models in the EAP series likely have a different platform
and the upgrade and image verification process differs.
OKLI kernel loader is required because the OEM software
expects the kernel to be no greater than 1536k
and the factory.bin upgrade procedure would
overwrite part of the kernel when writing rootfs.
Note on PLL-data cells:
The default PLL register values will not work
because of the external AR8035-A switch between
the SOC and the ethernet PHY chips.
For AR934x series, the PLL register for GMAC0
can be seen in the DTSI as 0x2c.
Therefore the PLL register can be read from uboot
for each link speed after attempting tftpboot
or another network action using that link speed
with `md 0x1805002c 1`.
Unfortunately uboot did not have the best values
so they were taken from other similar DTS files.
Tested from master, all link speeds functional
Signed-off-by: Michael Pratt <mcpratt@pm.me>
FCC ID: A8J-ECB600
Engenius ECB600 is a wireless access point with 1 gigabit PoE ethernet port,
dual-band wireless, external ethernet switch, and 4 external antennas.
Specification:
- AR9344 SOC (5 GHz, 2x2, WMAC)
- AR9382 WLAN (2.4 GHz, 2x2, PCIe on-board)
- AR8035-A switch (GbE with 802.3af PoE)
- 40 MHz reference clock
- 16 MB FLASH MX25L12845EMI-10G
- 2x 64 MB RAM NT5TU32M16DG
- UART at H1 (populated)
- 4 LEDs, 1 button (power, eth, 2.4 GHz, 5 GHz) (reset)
- 4 external antennas
MAC addresses:
MAC addresses are labeled MAC1 and MAC2
The MAC address in flash is not on the label
The OEM software reports these MACs for the ifconfig
phy1 MAC 1 *:52 --- (2.4 GHz)
phy0 MAC 2 *:53 --- (5 GHz)
eth0 ----- *:54 art 0x0
Installation:
2 ways to flash factory.bin from OEM:
- if you get Failsafe Mode from failed flash:
only use it to flash Original firmware from Engenius
or risk kernel loop or halt which requires serial cable
Method 1: Firmware upgrade page:
OEM webpage at 192.168.1.1
username and password "admin"
Navigate to "Upgrade Firmware" page from left pane
Click Browse and select the factory.bin image
Upload and verify checksum
Click Continue to confirm and wait 3 minutes
Method 2: Serial to load Failsafe webpage:
After connecting to serial console and rebooting...
Interrupt uboot with any key pressed rapidly
execute `run failsafe_boot` OR `bootm 0x9fdf0000`
wait a minute
connect to ethernet and navigate to
"192.168.1.1/index.htm"
Select the factory.bin image and upload
wait about 3 minutes
Return to OEM:
If you have a serial cable, see Serial Failsafe instructions
otherwise, uboot-env can be used to make uboot load the failsafe image
*DISCLAIMER*
The Failsafe image is unique to Engenius boards.
If the failsafe image is missing or damaged this will not work
DO NOT downgrade to ar71xx this way, it can cause kernel loop or halt
ssh into openwrt and run
`fw_setenv rootfs_checksum 0`
reboot, wait 3 minutes
connect to ethernet and navigate to 192.168.1.1/index.htm
select OEM firmware image from Engenius and click upgrade
Format of OEM firmware image:
The OEM software of ECB600 is a heavily modified version
of Openwrt Kamikaze. One of the many modifications
is to the sysupgrade program. Image verification is performed
simply by the successful ungzip and untar of the supplied file
and name check and header verification of the resulting contents.
To form a factory.bin that is accepted by OEM Openwrt build,
the kernel and rootfs must have specific names...
openwrt-senao-ecb600-uImage-lzma.bin
openwrt-senao-ecb600-root.squashfs
and begin with the respective headers (uImage, squashfs).
Then the files must be tarballed and gzipped.
The resulting binary is actually a tar.gz file in disguise.
This can be verified by using binwalk on the OEM firmware images,
ungzipping then untaring.
The OEM upgrade script is at /etc/fwupgrade.sh
Later models in the ECB series likely have a different platform
and the upgrade and image verification process differs.
OKLI kernel loader is required because the OEM software
expects the kernel to be no greater than 1536k
and the factory.bin upgrade procedure would
overwrite part of the kernel when writing rootfs.
Note on PLL-data cells:
The default PLL register values will not work
because of the external AR8035-A switch between
the SOC and the ethernet PHY chips.
For AR934x series, the PLL register for GMAC0
can be seen in the DTSI as 0x2c.
Therefore the PLL register can be read from uboot
for each link speed after attempting tftpboot
or another network action using that link speed
with `md 0x1805002c 1`.
Unfortunately uboot did not have the best values
so they were taken from other similar DTS files.
Tested from master, all link speeds functional
Signed-off-by: Michael Pratt <mcpratt@pm.me>
FCC ID: A8J-ECB350
Engenius ECB350 v1 is an indoor wireless access point with a gigabit ethernet port,
2.4 GHz wireless, external antennas, and PoE.
**Specification:**
- AR7242 SOC
- AR9283 WLAN 2.4 GHz (2x2), PCIe on-board
- AR8035-A switch RGMII, GbE with 802.3af PoE
- 40 MHz reference clock
- 8 MB FLASH 25L6406EM2I-12G
- 32 MB RAM
- UART at J2 (populated)
- 2 external antennas
- 3 LEDs, 1 button (power, lan, wlan) (reset)
**MAC addresses:**
MACs are labeled as WLAN and WAN
vendor MAC addresses in flash are duplicate
phy0 WLAN *:b8 ---
eth0 WAN *:b9 art 0x0/0x6
**Installation:**
- if you get Failsafe Mode from failed flash:
only use it to flash Original firmware from Engenius
or risk kernel loop or halt which requires serial cable
Method 1: Firmware upgrade page:
OEM webpage at 192.168.1.1
username and password "admin"
Navigate to "Firmware" page from left pane
Click Browse and select the factory.bin image
Upload and verify checksum
Click Continue to confirm and wait 3 minutes
Method 2: Serial to load Failsafe webpage:
After connecting to serial console and rebooting...
Interrupt uboot with any key pressed rapidly
execute `run failsafe_boot` OR `bootm 0x9f670000`
wait a minute
connect to ethernet and navigate to
"192.168.1.1/index.htm"
Select the factory.bin image and upload
wait about 3 minutes
**Return to OEM:**
If you have a serial cable, see Serial Failsafe instructions
otherwise, uboot-env can be used to make uboot load the failsafe image
*DISCLAIMER*
The Failsafe image is unique to Engenius boards.
If the failsafe image is missing or damaged this will not work
DO NOT downgrade to ar71xx this way, it can cause kernel loop or halt
ssh into openwrt and run
`fw_setenv rootfs_checksum 0`
reboot, wait 3 minutes
connect to ethernet and navigate to 192.168.1.1/index.htm
select OEM firmware image from Engenius and click upgrade
**TFTP recovery** (unstable / not reliable):
rename initramfs to 'vmlinux-art-ramdisk'
make available on TFTP server at 192.168.1.101
power board while holding or pressing reset button repeatedly
NOTE: for some Engenius boards TFTP is not reliable
try setting MTU to 600 and try many times
**Format of OEM firmware image:**
The OEM software of ECB350 v1 is a heavily modified version
of Openwrt Kamikaze. One of the many modifications
is to the sysupgrade program. Image verification is performed
by the successful ungzip and untar of the supplied file
and name check and header verification of the resulting contents.
To form a factory.bin that is accepted by OEM Openwrt build,
the kernel and rootfs must have specific names
and begin with the respective headers (uImage, squashfs).
Then the files must be tarballed and gzipped.
The resulting binary is actually a tar.gz file in disguise.
This can be verified by using binwalk on the OEM firmware images,
ungzipping then untaring.
The OEM upgrade script is at /etc/fwupgrade.sh.
OKLI kernel loader is required because the OEM software
expects the kernel size to be no greater than 1536k
and otherwise the factory.bin upgrade procedure would
overwrite part of the kernel when writing rootfs.
The factory upgrade script follows the original mtd partitions.
**Note on PLL-data cells:**
The default PLL register values will not work
because of the AR8035 switch between
the SOC and the ethernet port.
For AR724x series, the PLL register for GMAC0
can be seen in the DTSI as 0x2c.
Therefore the PLL register can be read from u-boot
for each link speed after attempting tftpboot
or another network action using that link speed
with `md 0x1805002c 1`
However the registers that u-boot sets are not ideal and sometimes wrong...
the at803x driver supports setting the RGMII clock/data delay on the PHY side.
This way the pll-data register only needs to handle invert and phase.
for this board no extra adjustements are needed on the MAC side
all link speeds functional
Signed-off-by: Michael Pratt <mcpratt@pm.me>
factory.bin was not tested for ECB1750...
but it was tested on it's sister board ECB1200
The product ID for the header can be verified by inspecting
the header of OEM images, or in the u-boot environment.
Also:
- the LAN LED is controlled directly by the AR8035 switch
- the labelled (first increment) MAC for both is ethaddr (eth0)
- list packages in alphabetical order
- use default sysupgrade.bin recipe
Signed-off-by: Michael Pratt <mcpratt@pm.me>
FCC ID: A8J-ECB1200
Engenius ECB1200 is an indoor wireless access point with a GbE port,
2.4 GHz and 5 GHz wireless, external antennas, and 802.3af PoE.
**Specification:**
- QCA9557 SOC MIPS, 2.4 GHz (2x2)
- QCA9882 WLAN PCIe card, 5 GHz (2x2)
- AR8035-A switch RGMII, GbE with 802.3af PoE, 25 MHz clock
- 40 MHz reference clock
- 16 MB FLASH 25L12845EMI-10G
- 2x 64 MB RAM 1538ZFZ V59C1512164QEJ25
- UART at JP1 (unpopulated, RX shorted to ground)
- 4 external antennas
- 4 LEDs, 1 button (power, eth, wifi2g, wifi5g) (reset)
**MAC addresses:**
MAC Addresses are labeled as ETH and 5GHZ
U-boot environment has the vendor MAC addresses
MAC addresses in ART do not match vendor
eth0 ETH *:5c u-boot-env ethaddr
phy0 5GHZ *:5d u-boot-env athaddr
---- ---- ???? art 0x0/0x6
**Installation:**
Method 1: Firmware upgrade page:
OEM webpage at 192.168.1.1
username and password "admin"
Navigate to "Firmware" page from left pane
Click Browse and select the factory.bin image
Upload and verify checksum
Click Continue to confirm and wait 3 minutes
Method 2: Serial to load Failsafe webpage:
After connecting to serial console and rebooting...
Interrupt uboot with any key pressed rapidly
(see TFTP recovery)
perform a sysupgrade
**Serial Access:**
the RX line on the board for UART is shorted to ground by resistor R176
therefore it must be removed to use the console
but it is not necessary to remove to view boot log
optionally, R175 can be replaced with a solder bridge short
the resistors R175 and R176 are next to the UART pinout at JP1
**Return to OEM:**
If you have a serial cable, see Serial Failsafe instructions
Unlike most Engenius boards, this does not have a 'failsafe' image
the only way to return to OEM is TFTP or serial access to u-boot
**TFTP recovery:**
Unlike most Engenius boards, TFTP is reliable here
rename initramfs-kernel.bin to 'ap.bin'
make the file available on a TFTP server at 192.168.1.10
power board while holding or pressing reset button repeatedly
or with serial access:
run `tftpboot` or `run factory_boot` with initramfs-kernel.bin
then `bootm` with the load address
**Format of OEM firmware image:**
The OEM software of ECB1200 is a heavily modified version
of Openwrt Altitude Adjustment 12.09.
This Engenius board, like ECB1750, uses a proprietary header
with a unique Product ID. The header for factory.bin is
generated by the mksenaofw program included in openwrt.
**Note on PLL-data cells:**
The default PLL register values will not work
because of the AR8035 switch between
the SOC and the ethernet port.
For QCA955x series, the PLL registers for eth0 and eth1
can be see in the DTSI as 0x28 and 0x48 respectively.
Therefore the PLL registers can be read from uboot
for each link speed after attempting tftpboot
or another network action using that link speed
with `md 0x18050028 1` and `md 0x18050048 1`.
However the registers that u-boot sets are not ideal and sometimes wrong...
the at803x driver supports setting the RGMII clock/data delay on the PHY side.
This way the pll-data register only needs to handle invert and phase.
for this board clock invert is needed on the MAC side
all link speeds functional
Signed-off-by: Michael Pratt <mcpratt@pm.me>
AirTight Networks (later renamed to Mojo Networks) C-75 is a dual-band
access point, also sold by WatchGuard under name AP320.
Specification
SoC: Qualcomm Atheros QCA9550
RAM: 128 MiB DDR2
Flash: 2x 16 MiB SPI NOR
WIFI: 2.4 GHz 3T3R integrated
5 GHz 3T3R QCA9890 oversized Mini PCIe card
Ethernet: 2x 10/100/1000 Mbps QCA8334
port labeled LAN1 is PoE capable (802.3at)
USB: 1x 2.0
LEDs: 7x which two are GPIO controlled, four switch controlled, one
controlled by wireless driver
Buttons: 1x GPIO controlled
Serial: RJ-45 port, Cisco pinout
baud: 115200, parity: none, flow control: none
JTAG: Yes, pins marked J1 on PCB
Installation
1. Prepare TFTP server with OpenWrt initramfs-kernel image.
2. Connect to one of LAN ports.
3. Connect to serial port.
4. Power on the device and when prompted to stop autoboot, hit any key.
5. Adjust "ipaddr" and "serverip" addresses in U-Boot environment, use
'setenv' to do that, then run following commands:
tftpboot 0x81000000 <openwrt_initramfs-kernel_image_name>
bootm 0x81000000
6. Wait about 1 minute for OpenWrt to boot.
7. Transfer OpenWrt sysupgrade image to /tmp directory and flash it
with:
sysupgrade -n /tmp/<openwrt_sysupgrade_image_name>
8. After flashing, the access point will reboot to OpenWrt. Wait few
minutes, until the Power LED stops blinking, then it's ready for
configuration.
Known issues
Green power LED does not work.
Additional information
The U-Boot fails to initialise ethernet ports correctly when a UART
adapter is attached to UART pins (marked J3 on PCB).
Cc: Vladimir Georgievsky <vladimir.georgievsky@yahoo.com>
Signed-off-by: Tomasz Maciej Nowak <tmn505@gmail.com>
The ZyXEL GS1900-8HP is an 8 port gigabit switch with PoE+ support.
There are two versions on the market (v1 & v2) which share similar
specs (same flash size and flash layout, same RAM size, same PoE+ power
envelope) but have a different case and board layout that they each
share with other GS1900 siblings.
The v1 seems to share its PCB and case with non-PoE GS1900-8; as such,
adding support for the GS1900-8 would probably be trivial. The v2 seems
to share its casing and platform with its already supported bigger
brother, the GS1900-10HP - its board looks the same, except for two
holes where the GS1900-10 has its SFP ports.
Like their 10 port sibling, both devices have a dual firmware layout.
Both GS1900-8HP boards have the same 70W PoE+ power budget. In order to
manipulate the PoE+, one needs the rtl83xx-poe package [1].
After careful consideration it was decided to go with separate images
for each version.
Specifications (v1)
-------------------
* SoC: Realtek RTL8380M 500 MHz MIPS 4KEc
* Flash: Macronix MX25L12835F 16 MiB
* RAM: Nanya NT5TU128M8HE-AC 128 MiB DDR2 SDRAM
* Ethernet: 8x 10/100/1000 Mbit
* PoE+: Broadcom BCM59111KMLG (IEEE 802.3at-2009 compliant, 2x)
* UART: 1 serial header with populated standard pin connector on the
left side of the PCB, towards the bottom. Pins are labeled:
+ VCC (3.3V)
+ TX
+ RX
+ GND
Specifications (v2)
-------------------
* SoC: Realtek RTL8380M 500 MHz MIPS 4KEc
* Flash: Macronix MX25L12835F 16 MiB
* RAM: Samsung K4B1G0846G 128 MiB DDR3 SDRAM
* Ethernet: 8x 10/100/1000 Mbit
* PoE+: Broadcom BCM59121B0KMLG (IEEE 802.3at-2009 compliant)
* UART: 1 angled serial header with populated standard pin connector
accessible from outside through the ventilation slits on the
side. Pins from top to bottom are clearly marked on the PCB:
+ VCC (3.3V)
+ TX
+ RX
+ GND
Serial connection parameters for both devices: 115200 8N1.
Installation
------------
Instructions are identical to those for the GS1900-10HP and apply both
to the GS1900-8HP v1 and v2 as well.
* Configure your client with a static 192.168.1.x IP (e.g. 192.168.1.10).
* Set up a TFTP server on your client and make it serve the initramfs
image.
* Connect serial, power up the switch, interrupt U-boot by hitting the
space bar, and enable the network:
> rtk network on
* Since the GS1900-10HP is a dual-partition device, you want to keep the
OEM firmware on the backup partition for the time being. OpenWrt can
only boot off the first partition anyway (hardcoded in the DTS). To
make sure we are manipulating the first partition, issue the following
commands:
> setsys bootpartition 0
> savesys
* Download the image onto the device and boot from it:
> tftpboot 0x84f00000 192.168.1.10:openwrt-realtek-generic-zyxel_gs1900-8hp-v{1,2}-initramfs-kernel.bin
> bootm
* Once OpenWrt has booted, scp the sysupgrade image to /tmp and flash it:
> sysupgrade /tmp//tmp/openwrt-realtek-generic-zyxel_gs1900-8hp-v{1,2}-squashfs-sysupgrade.bin
Signed-off-by: Stijn Segers <foss@volatilesystems.org>
[merge PoE case, keep device definitions separate, change all those
hashes in the commit message to something else so they don't get
removed when changing the commit ...]
Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
The ZyXEL GS1900-8HP v1, v2 and GS1900-10HP are all built on a similar
Realtek RTL8380M platform. Create a common DTSI in preparation for
GS1900-8HP support, and switch to the macros defined in rtl838x.dtsi.
Signed-off-by: Stijn Segers <foss@volatilesystems.org>
[drop redundant includes, use &mdio directly, do not replace SFP
ports]
Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
Move the memory out of the rtl838x.dtsi and into the device family DTSI
or device DTS if applicable. This aligns with upstream practice.
Signed-off-by: Stijn Segers <foss@volatilesystems.org>
[add missing block for dgs-1210-10p, move block below chosen node]
Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
ZyXEL spells its own name all uppercase with just the Y lowercase. Adapt
the realtek target to follow this (other OpenWrt targets already do so).
Signed-off-by: Stijn Segers <foss@volatilesystems.org>
The identifier is already present in rtl838x.dtsi, and adding it
twice is not only redundant but actually wrong.
Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
For:
- ENH202 v1
- ENS202EXT v1
These boards were committed before it was discovered
that for all Engenius boards with a "failsafe" image,
forcing the failsafe image to load next boot
can be achieved by editing the u-boot environment like:
`fw_setenv rootfs_checksum 0`
So it's not necessary to delete a partition to boot to failsafe image.
Signed-off-by: Michael Pratt <mcpratt@pm.me>
imx6 has it's own pcie host driver so we do
not need the one from DW.
This fixes following boot error:
[ 0.156913] dw-pcie 1ffc000.pcie: IRQ index 1 not found
Fixes: 6d5291ff72 ("imx6: add support for kernel 5.4")
Signed-off-by: Tim Harvey <tharvey@gateworks.com>
Signed-off-by: Koen Vandeputte <koen.vandeputte@ncentric.com>
2 regulator descriptions carry identical naming.
This leads to following boot warning:
[ 0.173138] debugfs: Directory 'vdd1p8' with parent 'regulator' already present!
Fix this by renaming the one used for audio.
Signed-off-by: Koen Vandeputte <koen.vandeputte@ncentric.com>
It is good practice to define device tree files based on specific
SoCs. Thus, let's not start to create files that are used across
different architectures.
Duplicate the DTSI file for D-Link DAP-2xxx in order to have one
for qca953x and one for qca955x, respectively.
Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
The device is a one-port, but was set up as two-port by the
default case in 02_network. Fix it.
Signed-off-by: Sebastian Schaper <openwrt@sebastianschaper.net>
[commit title/message facelift]