Commit Graph

8305 Commits

Author SHA1 Message Date
CN_SZTL
33e4a1c124
Merge Mainline 2021-01-10 01:48:10 +08:00
CN_SZTL
b09ca4bd31
trojan-plus: Makefile cleanups 2021-01-10 01:46:12 +08:00
CN_SZTL
ab480debc9
trojan: Makefile cleanups 2021-01-10 01:41:26 +08:00
CN_SZTL
d7c56a425c
trojan-go: cleanup Makefile 2021-01-10 01:32:58 +08:00
CN_SZTL
a560911888
kernel: bump to 4.9.250, 4.14.214, 4.19.166
Refreshed all patches.

Signed-off-by: CN_SZTL <cnsztl@project-openwrt.eu.org>
2021-01-10 00:12:43 +08:00
CN_SZTL
093f5840b5
Merge Mainline 2021-01-09 23:43:09 +08:00
Mattraks
c8d5b8b7a0
luci-app-ssr-plus: bug fixes 2021-01-09 23:39:50 +08:00
CN_SZTL
bf5f966f29
subconverter: bump to latest git HEAD and Makefile cleanups 2021-01-09 23:35:47 +08:00
CN_SZTL
141af89d8f
rapidjson: bump to latest git HAD 2021-01-09 22:58:46 +08:00
CN_SZTL
ea67f1ccfa
jpcre2: Makefile cleanup 2021-01-09 22:50:12 +08:00
CN_SZTL
d1786b3219
rapidjson: Makefile cleanup 2021-01-09 22:43:37 +08:00
CN_SZTL
059a2c9e65
smartdns: backport upstream fixes 2021-01-09 21:33:55 +08:00
ericsnow911
1d4cca095a
ramips: fix LEDs status for XiaoMi R3P 2021-01-09 21:10:45 +08:00
CN_SZTL
c9405b4f32
luci-app-clash: remove outdated package 2021-01-09 21:03:26 +08:00
秦宇航
4a4fcd8411
verysync: update to v2.4.2 2021-01-09 20:46:44 +08:00
CN_SZTL
8f0a48a9a6
Merge Mainline 2021-01-09 17:09:00 +08:00
CN_SZTL
e9825ca5bd
rockchip: remove redundant usb-net dependencies 2021-01-09 17:07:45 +08:00
CN_SZTL
acca65e43e
Revert "r8152: drop package"
Fix dependencies for old kernel modules.
Fixes: f00092526d ("r8152: add package")

This reverts commit 6a0986fa4e.
2021-01-09 17:02:43 +08:00
CN_SZTL
5cc1d3df78
rockchip: improve support for NanoPi R4S
- enable sd ultra-high speeds
- format style

Fixes: cd7fd0c77b ("rockchip: add NanoPi R4S support")

Signed-off-by: CN_SZTL <cnsztl@project-openwrt.eu.org>
2021-01-09 16:45:53 +08:00
Tomasz Maciej Nowak
64165c388f
ath79: airtight c-75: use second flash chip
The flash capacity is divided in two flash chips and currently only
first is used. Increase available space for OpenWrt by additional 16 MiB
using mtd-concat driver. Because U-Boot might not be able to load kernel
image spanned through two flash chips, the size of kernel is limited
to space available on first first chip.

Cc: Vladimir Georgievsky <vladimir.georgievsky@yahoo.com>
Signed-off-by: Tomasz Maciej Nowak <tmn505@gmail.com>
2021-01-09 16:39:29 +08:00
Martin Blumenstingl
abf73b0e66
ath79: add support for the Belkin F9K1115 v2 (AC1750 DB Wi-Fi)
This device has (almost?) identical hardware to the F9J1108 v2 but uses
a different firmware magic and model number.

Specifications:

SoC: QCA9558
CPU: 720 MHz
Flash: 16 MiB NOR
RAM: 128 MiB
WiFi 2.4 GHz: QCA9558-AT4A 3x3 MIMO 802.11b/g/n
WiFi 5 GHz: QCA9880-2R4E 3x3 MIMO 802.11a/n/ac
Ethernet: 4x LAN and 1x WAN (all 1Gbit/s ports)
USB: 1 x USB 2.0 (lower), 1 x USB 3.0 (upper)

MAC addresses based on OEM firmware:

Interface   Address   Location
---------   -------   --------
lan         *:5A      sometimes in 0x6
wan         *:5B      0x0
2.4Ghz      *:5A      0x1002
5Ghz        As per mini PCIe EEPROM

Flashing instructions:

The factory.bin can be flashed via the Belkin web UI or via the uboot
HTTP upgrade page (which is by default listening on 192.168.2.1). Once
the factory.bin has been written, sysupgrade.bin will work as usual.

Signed-off-by: Martin Blumenstingl <martin.blumenstingl@googlemail.com>
2021-01-09 16:39:13 +08:00
Michael Pratt
37b38d6e01
ath79: move small-flash Engenius boards to tiny
This moves some of the Engenius boards from generic to tiny:

 - EAP350 v1
 - ECB350 v1
 - ENH202 v1

For these, factory.bin builds are already failing on master
branch because of the unique situation for these boards:

 - 8 MB flash
 - an extra "failsafe" image for recovery
 - TFTP does not work (barely possible with 600 MTU)
 - bootloader loads image from a longer flash offset
 - 1 eraseblock each needed for OKLI kernel loader and fake rootfs
 - using mtd-concat to make use of remaining space...

The manual alternative would be removing the failsafe partition.
However this comes with the risk of extremely difficult recovery
if a flash ever fails because TFTP on the bootloader is bugged.
Signed-off-by: Michael Pratt <mcpratt@pm.me>
[improve commit message]
Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
2021-01-09 16:38:25 +08:00
Martin Blumenstingl
46ec43607d
ath79: create shared DTSI/definition for Belkin F9J1108/F9K1115 v2
Belkin F9J1108 v2 and F9K1115 v2 are (seemingly) identical hardware
with different model numbers. Extract all non-device specific code to a
common .dtsi so it can be re-used when adding support for the
F9K1115 v2.

Similar to the .dtsi most of the image building recipe code can be
re-used. Move everything except the device model, edimax header magic
and edimax header model into a shared build recipe.

Signed-off-by: Martin Blumenstingl <martin.blumenstingl@googlemail.com>
[drop duplicate TARGET_DEVICES, add EDIMAX_* to DEVICE_VARS, edit title]
Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
2021-01-09 16:37:37 +08:00
Michael Pratt
45d66945a4
ath79: add support for Senao Engenius EAP350 v1
FCC ID: U2M-EAP350

Engenius EAP350 is a wireless access point with 1 gigabit PoE ethernet port,
2.4 GHz wireless, external ethernet switch, and 2 internal antennas.

Specification:

  - AR7242 SOC
  - AR9283 WLAN			(2.4 GHz, 2x2, PCIe on-board)
  - AR8035-A switch		(GbE with 802.3af PoE)
  - 40 MHz reference clock
  - 8 MB FLASH			MX25L6406E
  - 32 MB RAM			EM6AA160TSA-5G
  - UART at J2			(populated)
  - 3 LEDs, 1 button		(power, eth, 2.4 GHz) (reset)
  - 2 internal antennas

MAC addresses:

  MAC address is labeled as "MAC"
  Only 1 address on label and in flash
  The OEM software reports these MACs for the ifconfig

  eth0	MAC	*:0c	art 0x0
  phy0	---	*:0d	---

Installation:

  2 ways to flash factory.bin from OEM:

  - if you get Failsafe Mode from failed flash:
      only use it to flash Original firmware from Engenius
      or risk kernel loop or halt which requires serial cable

  Method 1: Firmware upgrade page:

    OEM webpage at 192.168.10.1
    username and password "admin"
    Navigate to "Upgrade Firmware" page from left pane
    Click Browse and select the factory.bin image
    Upload and verify checksum
    Click Continue to confirm and wait 3 minutes

  Method 2: Serial to load Failsafe webpage:

    After connecting to serial console and rebooting...
    Interrupt uboot with any key pressed rapidly
    execute `run failsafe_boot` OR `bootm 0x9f670000`
    wait a minute
    connect to ethernet and navigate to
    "192.168.1.1/index.htm"
    Select the factory.bin image and upload
    wait about 3 minutes

Return to OEM:

  If you have a serial cable, see Serial Failsafe instructions
  otherwise, uboot-env can be used to make uboot load the failsafe image

  *DISCLAIMER*
  The Failsafe image is unique to Engenius boards.
  If the failsafe image is missing or damaged this will not work
  DO NOT downgrade to ar71xx this way, it can cause kernel loop or halt

  ssh into openwrt and run
  `fw_setenv rootfs_checksum 0`
  reboot, wait 3 minutes
  connect to ethernet and navigate to 192.168.1.1/index.htm
  select OEM firmware image from Engenius and click upgrade

Format of OEM firmware image:

  The OEM software of EAP350 is a heavily modified version
  of Openwrt Kamikaze. One of the many modifications
  is to the sysupgrade program. Image verification is performed
  simply by the successful ungzip and untar of the supplied file
  and name check and header verification of the resulting contents.
  To form a factory.bin that is accepted by OEM Openwrt build,
  the kernel and rootfs must have specific names...

    openwrt-senao-eap350-uImage-lzma.bin
    openwrt-senao-eap350-root.squashfs

  and begin with the respective headers (uImage, squashfs).
  Then the files must be tarballed and gzipped.
  The resulting binary is actually a tar.gz file in disguise.
  This can be verified by using binwalk on the OEM firmware images,
  ungzipping then untaring.

  The OEM upgrade script is at /etc/fwupgrade.sh

  Later models in the EAP series likely have a different platform
  and the upgrade and image verification process differs.

  OKLI kernel loader is required because the OEM software
  expects the kernel to be no greater than 1024k
  and the factory.bin upgrade procedure would
  overwrite part of the kernel when writing rootfs.

Note on PLL-data cells:

  The default PLL register values will not work
  because of the external AR8035-A switch between
  the SOC and the ethernet PHY chips.

  For AR724x series, the PLL register for GMAC0
  can be seen in the DTSI as 0x2c.
  Therefore the PLL register can be read from uboot
  for each link speed after attempting tftpboot
  or another network action using that link speed
  with `md 0x1805002c 1`.

  uboot did not have a good value for 1 GBps
  so it was taken from other similar DTS file.

Tested from master, all link speeds functional

Signed-off-by: Michael Pratt <mcpratt@pm.me>
2021-01-09 16:31:30 +08:00
Michael Pratt
f219058957
ath79: add support for Senao Engenius EAP600
FCC ID: A8J-EAP600

Engenius EAP600 is a wireless access point with 1 gigabit ethernet port,
dual-band wireless, external ethernet switch, 4 internal antennas
and 802.3af PoE.

Specification:

  - AR9344 SOC			(5 GHz, 2x2, WMAC)
  - AR9382 WLAN			(2.4 GHz, 2x2, PCIe on-board)
  - AR8035-A switch		(GbE with 802.3af PoE)
  - 40 MHz reference clock
  - 16 MB FLASH			MX25L12845EMI-10G
  - 2x 64 MB RAM		NT5TU32M16DG
  - UART at H1			(populated)
  - 5 LEDs, 1 button		(power, eth, 2.4 GHz, 5 GHz, wps) (reset)
  - 4 internal antennas

MAC addresses:

  MAC addresses are labeled MAC1 and MAC2
  The MAC address in flash is not on the label
  The OEM software reports these MACs for the ifconfig

  eth0	MAC 1	*:5e	---
  phy1	MAC 2	*:5f	---	(2.4 GHz)
  phy0	-----	*:60	art 0x0	(5 GHz)

Installation:

  2 ways to flash factory.bin from OEM:

  - if you get Failsafe Mode from failed flash:
      only use it to flash Original firmware from Engenius
      or risk kernel loop or halt which requires serial cable

  Method 1: Firmware upgrade page:

    OEM webpage at 192.168.1.1
    username and password "admin"
    Navigate to "Upgrade Firmware" page from left pane
    Click Browse and select the factory.bin image
    Upload and verify checksum
    Click Continue to confirm and wait 3 minutes

  Method 2: Serial to load Failsafe webpage:

    After connecting to serial console and rebooting...
    Interrupt uboot with any key pressed rapidly
    execute `run failsafe_boot` OR `bootm 0x9fdf0000`
    wait a minute
    connect to ethernet and navigate to
    "192.168.1.1/index.htm"
    Select the factory.bin image and upload
    wait about 3 minutes

Return to OEM:

  If you have a serial cable, see Serial Failsafe instructions
  otherwise, uboot-env can be used to make uboot load the failsafe image

  *DISCLAIMER*
  The Failsafe image is unique to Engenius boards.
  If the failsafe image is missing or damaged this will not work
  DO NOT downgrade to ar71xx this way, it can cause kernel loop or halt

  ssh into openwrt and run
  `fw_setenv rootfs_checksum 0`
  reboot, wait 3 minutes
  connect to ethernet and navigate to 192.168.1.1/index.htm
  select OEM firmware image from Engenius and click upgrade

Format of OEM firmware image:

  The OEM software of EAP600 is a heavily modified version
  of Openwrt Kamikaze. One of the many modifications
  is to the sysupgrade program. Image verification is performed
  simply by the successful ungzip and untar of the supplied file
  and name check and header verification of the resulting contents.
  To form a factory.bin that is accepted by OEM Openwrt build,
  the kernel and rootfs must have specific names...

    openwrt-senao-eap600-uImage-lzma.bin
    openwrt-senao-eap600-root.squashfs

  and begin with the respective headers (uImage, squashfs).
  Then the files must be tarballed and gzipped.
  The resulting binary is actually a tar.gz file in disguise.
  This can be verified by using binwalk on the OEM firmware images,
  ungzipping then untaring.

  The OEM upgrade script is at /etc/fwupgrade.sh

  Later models in the EAP series likely have a different platform
  and the upgrade and image verification process differs.

  OKLI kernel loader is required because the OEM software
  expects the kernel to be no greater than 1536k
  and the factory.bin upgrade procedure would
  overwrite part of the kernel when writing rootfs.

Note on PLL-data cells:

  The default PLL register values will not work
  because of the external AR8035-A switch between
  the SOC and the ethernet PHY chips.

  For AR934x series, the PLL register for GMAC0
  can be seen in the DTSI as 0x2c.
  Therefore the PLL register can be read from uboot
  for each link speed after attempting tftpboot
  or another network action using that link speed
  with `md 0x1805002c 1`.

  Unfortunately uboot did not have the best values
  so they were taken from other similar DTS files.

Tested from master, all link speeds functional

Signed-off-by: Michael Pratt <mcpratt@pm.me>
2021-01-09 16:31:24 +08:00
Michael Pratt
3f13892b9e
ath79: add support for Senao Engenius ECB600
FCC ID: A8J-ECB600

Engenius ECB600 is a wireless access point with 1 gigabit PoE ethernet port,
dual-band wireless, external ethernet switch, and 4 external antennas.

Specification:

  - AR9344 SOC			(5 GHz, 2x2, WMAC)
  - AR9382 WLAN			(2.4 GHz, 2x2, PCIe on-board)
  - AR8035-A switch		(GbE with 802.3af PoE)
  - 40 MHz reference clock
  - 16 MB FLASH			MX25L12845EMI-10G
  - 2x 64 MB RAM		NT5TU32M16DG
  - UART at H1			(populated)
  - 4 LEDs, 1 button		(power, eth, 2.4 GHz, 5 GHz) (reset)
  - 4 external antennas

MAC addresses:

  MAC addresses are labeled MAC1 and MAC2
  The MAC address in flash is not on the label
  The OEM software reports these MACs for the ifconfig

  phy1	MAC 1	*:52	---	(2.4 GHz)
  phy0	MAC 2	*:53	---	(5 GHz)
  eth0	-----	*:54	art 0x0

Installation:

  2 ways to flash factory.bin from OEM:

  - if you get Failsafe Mode from failed flash:
      only use it to flash Original firmware from Engenius
      or risk kernel loop or halt which requires serial cable

  Method 1: Firmware upgrade page:

    OEM webpage at 192.168.1.1
    username and password "admin"
    Navigate to "Upgrade Firmware" page from left pane
    Click Browse and select the factory.bin image
    Upload and verify checksum
    Click Continue to confirm and wait 3 minutes

  Method 2: Serial to load Failsafe webpage:

    After connecting to serial console and rebooting...
    Interrupt uboot with any key pressed rapidly
    execute `run failsafe_boot` OR `bootm 0x9fdf0000`
    wait a minute
    connect to ethernet and navigate to
    "192.168.1.1/index.htm"
    Select the factory.bin image and upload
    wait about 3 minutes

Return to OEM:

  If you have a serial cable, see Serial Failsafe instructions
  otherwise, uboot-env can be used to make uboot load the failsafe image

  *DISCLAIMER*
  The Failsafe image is unique to Engenius boards.
  If the failsafe image is missing or damaged this will not work
  DO NOT downgrade to ar71xx this way, it can cause kernel loop or halt

  ssh into openwrt and run
  `fw_setenv rootfs_checksum 0`
  reboot, wait 3 minutes
  connect to ethernet and navigate to 192.168.1.1/index.htm
  select OEM firmware image from Engenius and click upgrade

Format of OEM firmware image:

  The OEM software of ECB600 is a heavily modified version
  of Openwrt Kamikaze. One of the many modifications
  is to the sysupgrade program. Image verification is performed
  simply by the successful ungzip and untar of the supplied file
  and name check and header verification of the resulting contents.
  To form a factory.bin that is accepted by OEM Openwrt build,
  the kernel and rootfs must have specific names...

    openwrt-senao-ecb600-uImage-lzma.bin
    openwrt-senao-ecb600-root.squashfs

  and begin with the respective headers (uImage, squashfs).
  Then the files must be tarballed and gzipped.
  The resulting binary is actually a tar.gz file in disguise.
  This can be verified by using binwalk on the OEM firmware images,
  ungzipping then untaring.

  The OEM upgrade script is at /etc/fwupgrade.sh

  Later models in the ECB series likely have a different platform
  and the upgrade and image verification process differs.

  OKLI kernel loader is required because the OEM software
  expects the kernel to be no greater than 1536k
  and the factory.bin upgrade procedure would
  overwrite part of the kernel when writing rootfs.

Note on PLL-data cells:

  The default PLL register values will not work
  because of the external AR8035-A switch between
  the SOC and the ethernet PHY chips.

  For AR934x series, the PLL register for GMAC0
  can be seen in the DTSI as 0x2c.
  Therefore the PLL register can be read from uboot
  for each link speed after attempting tftpboot
  or another network action using that link speed
  with `md 0x1805002c 1`.

  Unfortunately uboot did not have the best values
  so they were taken from other similar DTS files.

Tested from master, all link speeds functional

Signed-off-by: Michael Pratt <mcpratt@pm.me>
2021-01-09 16:31:14 +08:00
Michael Pratt
0bff1678a0
ath79: add support for Senao Engenius ECB350 v1
FCC ID: A8J-ECB350

Engenius ECB350 v1 is an indoor wireless access point with a gigabit ethernet port,
2.4 GHz wireless, external antennas, and PoE.

**Specification:**

  - AR7242 SOC
  - AR9283 WLAN			2.4 GHz (2x2), PCIe on-board
  - AR8035-A switch		RGMII, GbE with 802.3af PoE
  - 40 MHz reference clock
  - 8 MB FLASH			25L6406EM2I-12G
  - 32 MB RAM
  - UART at J2			(populated)
  - 2 external antennas
  - 3 LEDs, 1 button		(power, lan, wlan) (reset)

**MAC addresses:**

  MACs are labeled as WLAN and WAN
  vendor MAC addresses in flash are duplicate

  phy0	WLAN	*:b8	---
  eth0	WAN	*:b9	art 0x0/0x6

**Installation:**

  - if you get Failsafe Mode from failed flash:
      only use it to flash Original firmware from Engenius
      or risk kernel loop or halt which requires serial cable

  Method 1: Firmware upgrade page:

  OEM webpage at 192.168.1.1
  username and password "admin"
  Navigate to "Firmware" page from left pane
  Click Browse and select the factory.bin image
  Upload and verify checksum
  Click Continue to confirm and wait 3 minutes

  Method 2: Serial to load Failsafe webpage:

  After connecting to serial console and rebooting...
  Interrupt uboot with any key pressed rapidly
  execute `run failsafe_boot` OR `bootm 0x9f670000`
  wait a minute
  connect to ethernet and navigate to
  "192.168.1.1/index.htm"
  Select the factory.bin image and upload
  wait about 3 minutes

**Return to OEM:**

  If you have a serial cable, see Serial Failsafe instructions
  otherwise, uboot-env can be used to make uboot load the failsafe image

  *DISCLAIMER*
  The Failsafe image is unique to Engenius boards.
  If the failsafe image is missing or damaged this will not work
  DO NOT downgrade to ar71xx this way, it can cause kernel loop or halt

  ssh into openwrt and run
  `fw_setenv rootfs_checksum 0`
  reboot, wait 3 minutes
  connect to ethernet and navigate to 192.168.1.1/index.htm
  select OEM firmware image from Engenius and click upgrade

**TFTP recovery** (unstable / not reliable):

  rename initramfs to 'vmlinux-art-ramdisk'
  make available on TFTP server at 192.168.1.101
  power board while holding or pressing reset button repeatedly

  NOTE: for some Engenius boards TFTP is not reliable
  try setting MTU to 600 and try many times

**Format of OEM firmware image:**

  The OEM software of ECB350 v1 is a heavily modified version
  of Openwrt Kamikaze. One of the many modifications
  is to the sysupgrade program. Image verification is performed
  by the successful ungzip and untar of the supplied file
  and name check and header verification of the resulting contents.
  To form a factory.bin that is accepted by OEM Openwrt build,
  the kernel and rootfs must have specific names
  and begin with the respective headers (uImage, squashfs).
  Then the files must be tarballed and gzipped.
  The resulting binary is actually a tar.gz file in disguise.
  This can be verified by using binwalk on the OEM firmware images,
  ungzipping then untaring.

  The OEM upgrade script is at /etc/fwupgrade.sh.

  OKLI kernel loader is required because the OEM software
  expects the kernel size to be no greater than 1536k
  and otherwise the factory.bin upgrade procedure would
  overwrite part of the kernel when writing rootfs.
  The factory upgrade script follows the original mtd partitions.

**Note on PLL-data cells:**

  The default PLL register values will not work
  because of the AR8035 switch between
  the SOC and the ethernet port.

  For AR724x series, the PLL register for GMAC0
  can be seen in the DTSI as 0x2c.
  Therefore the PLL register can be read from u-boot
  for each link speed after attempting tftpboot
  or another network action using that link speed
  with `md 0x1805002c 1`

  However the registers that u-boot sets are not ideal and sometimes wrong...
  the at803x driver supports setting the RGMII clock/data delay on the PHY side.
  This way the pll-data register only needs to handle invert and phase.

  for this board no extra adjustements are needed on the MAC side
  all link speeds functional

Signed-off-by: Michael Pratt <mcpratt@pm.me>
2021-01-09 16:28:50 +08:00
Michael Pratt
b5428e98d6
ath79: enable factory.bin and adjust profile of ECB1750
factory.bin was not tested for ECB1750...
but it was tested on it's sister board ECB1200

The product ID for the header can be verified by inspecting
the header of OEM images, or in the u-boot environment.

Also:

  - the LAN LED is controlled directly by the AR8035 switch
  - the labelled (first increment) MAC for both is ethaddr (eth0)
  - list packages in alphabetical order
  - use default sysupgrade.bin recipe

Signed-off-by: Michael Pratt <mcpratt@pm.me>
2021-01-09 16:28:43 +08:00
Michael Pratt
c70655e28f
ath79: add support for Senao Engenius ECB1200
FCC ID: A8J-ECB1200

Engenius ECB1200 is an indoor wireless access point with a GbE port,
2.4 GHz and 5 GHz wireless, external antennas, and 802.3af PoE.

**Specification:**

  - QCA9557 SOC			MIPS, 2.4 GHz (2x2)
  - QCA9882 WLAN		PCIe card, 5 GHz (2x2)
  - AR8035-A switch		RGMII, GbE with 802.3af PoE, 25 MHz clock
  - 40 MHz reference clock
  - 16 MB FLASH			25L12845EMI-10G
  - 2x 64 MB RAM		1538ZFZ V59C1512164QEJ25
  - UART at JP1			(unpopulated, RX shorted to ground)
  - 4 external antennas
  - 4 LEDs, 1 button		(power, eth, wifi2g, wifi5g) (reset)

**MAC addresses:**

  MAC Addresses are labeled as ETH and 5GHZ
  U-boot environment has the vendor MAC addresses
  MAC addresses in ART do not match vendor

  eth0	ETH	*:5c	u-boot-env ethaddr
  phy0	5GHZ	*:5d	u-boot-env athaddr
  ----	----	????	art 0x0/0x6

**Installation:**

  Method 1: Firmware upgrade page:

  OEM webpage at 192.168.1.1
  username and password "admin"
  Navigate to "Firmware" page from left pane
  Click Browse and select the factory.bin image
  Upload and verify checksum
  Click Continue to confirm and wait 3 minutes

  Method 2: Serial to load Failsafe webpage:

  After connecting to serial console and rebooting...
  Interrupt uboot with any key pressed rapidly

  (see TFTP recovery)
  perform a sysupgrade

**Serial Access:**

  the RX line on the board for UART is shorted to ground by resistor R176
  therefore it must be removed to use the console
  but it is not necessary to remove to view boot log
  optionally, R175 can be replaced with a solder bridge short

  the resistors R175 and R176 are next to the UART pinout at JP1

**Return to OEM:**

  If you have a serial cable, see Serial Failsafe instructions

  Unlike most Engenius boards, this does not have a 'failsafe' image
  the only way to return to OEM is TFTP or serial access to u-boot

**TFTP recovery:**

  Unlike most Engenius boards, TFTP is reliable here

  rename initramfs-kernel.bin to 'ap.bin'
  make the file available on a TFTP server at 192.168.1.10
  power board while holding or pressing reset button repeatedly

  or with serial access:
  run `tftpboot` or `run factory_boot` with initramfs-kernel.bin
  then `bootm` with the load address

**Format of OEM firmware image:**

  The OEM software of ECB1200 is a heavily modified version
  of Openwrt Altitude Adjustment 12.09.

  This Engenius board, like ECB1750, uses a proprietary header
  with a unique Product ID. The header for factory.bin is
  generated by the mksenaofw program included in openwrt.

**Note on PLL-data cells:**

  The default PLL register values will not work
  because of the AR8035 switch between
  the SOC and the ethernet port.

  For QCA955x series, the PLL registers for eth0 and eth1
  can be see in the DTSI as 0x28 and 0x48 respectively.
  Therefore the PLL registers can be read from uboot
  for each link speed after attempting tftpboot
  or another network action using that link speed
  with `md 0x18050028 1` and `md 0x18050048 1`.

  However the registers that u-boot sets are not ideal and sometimes wrong...
  the at803x driver supports setting the RGMII clock/data delay on the PHY side.
  This way the pll-data register only needs to handle invert and phase.

  for this board clock invert is needed on the MAC side
  all link speeds functional

Signed-off-by: Michael Pratt <mcpratt@pm.me>
2021-01-09 16:26:53 +08:00
Tomasz Maciej Nowak
6a16156857
ath79: add support for AirTight C-75
AirTight Networks (later renamed to Mojo Networks) C-75 is a dual-band
access point, also sold by WatchGuard under name AP320.

Specification
SoC: Qualcomm Atheros QCA9550
RAM: 128 MiB DDR2
Flash: 2x 16 MiB SPI NOR
WIFI: 2.4 GHz 3T3R integrated
      5 GHz 3T3R QCA9890 oversized Mini PCIe card
Ethernet: 2x 10/100/1000 Mbps QCA8334
          port labeled LAN1 is PoE capable (802.3at)
USB: 1x 2.0
LEDs: 7x which two are GPIO controlled, four switch controlled, one
      controlled by wireless driver
Buttons: 1x GPIO controlled
Serial: RJ-45 port, Cisco pinout
        baud: 115200, parity: none, flow control: none
JTAG: Yes, pins marked J1 on PCB

Installation
1. Prepare TFTP server with OpenWrt initramfs-kernel image.
2. Connect to one of LAN ports.
3. Connect to serial port.
4. Power on the device and when prompted to stop autoboot, hit any key.
5. Adjust "ipaddr" and "serverip" addresses in U-Boot environment, use
   'setenv' to do that, then run following commands:
    tftpboot 0x81000000 <openwrt_initramfs-kernel_image_name>
    bootm 0x81000000
6. Wait about 1 minute for OpenWrt to boot.
7. Transfer OpenWrt sysupgrade image to /tmp directory and flash it
   with:
    sysupgrade -n /tmp/<openwrt_sysupgrade_image_name>
8. After flashing, the access point will reboot to OpenWrt. Wait few
   minutes, until the Power LED stops blinking, then it's ready for
   configuration.

Known issues
Green power LED does not work.

Additional information
The U-Boot fails to initialise ethernet ports correctly when a UART
adapter is attached to UART pins (marked J3 on PCB).

Cc: Vladimir Georgievsky <vladimir.georgievsky@yahoo.com>
Signed-off-by: Tomasz Maciej Nowak <tmn505@gmail.com>
2021-01-09 16:26:46 +08:00
Stijn Segers
b66122951a
realtek: add support for ZyXEL GS1900-8HP v1 and v2
The ZyXEL GS1900-8HP is an 8 port gigabit switch with PoE+ support.
There are two versions on the market (v1 & v2) which share similar
specs (same flash size and flash layout, same RAM size, same PoE+ power
envelope) but have a different case and board layout that they each
share with other GS1900 siblings.

The v1 seems to share its PCB and case with non-PoE GS1900-8; as such,
adding support for the GS1900-8 would probably be trivial. The v2 seems
to share its casing and platform with its already supported bigger
brother, the GS1900-10HP - its board looks the same, except for two
holes where the GS1900-10 has its SFP ports.

Like their 10 port sibling, both devices have a dual firmware layout.
Both GS1900-8HP boards have the same 70W PoE+ power budget. In order to
manipulate the PoE+, one needs the rtl83xx-poe package [1].

After careful consideration it was decided to go with separate images
for each version.

Specifications (v1)
-------------------
* SoC:       Realtek RTL8380M 500 MHz MIPS 4KEc
* Flash:     Macronix MX25L12835F 16 MiB
* RAM:       Nanya NT5TU128M8HE-AC 128 MiB DDR2 SDRAM
* Ethernet:  8x 10/100/1000 Mbit
* PoE+:      Broadcom BCM59111KMLG (IEEE 802.3at-2009 compliant, 2x)
* UART:      1 serial header with populated standard pin connector on the
             left side of the PCB, towards the bottom. Pins are labeled:
             + VCC (3.3V)
             + TX
             + RX
             + GND

Specifications (v2)
-------------------
* SoC:       Realtek RTL8380M 500 MHz MIPS 4KEc
* Flash:     Macronix MX25L12835F 16 MiB
* RAM:       Samsung K4B1G0846G 128 MiB DDR3 SDRAM
* Ethernet:  8x 10/100/1000 Mbit
* PoE+:      Broadcom BCM59121B0KMLG (IEEE 802.3at-2009 compliant)
* UART:      1 angled serial header with populated standard pin connector
             accessible from outside through the ventilation slits on the
             side. Pins from top to bottom are clearly marked on the PCB:
             + VCC (3.3V)
             + TX
             + RX
             + GND

Serial connection parameters for both devices: 115200 8N1.

Installation
------------
Instructions are identical to those for the GS1900-10HP and apply both
to the GS1900-8HP v1 and v2 as well.

* Configure your client with a static 192.168.1.x IP (e.g. 192.168.1.10).
* Set up a TFTP server on your client and make it serve the initramfs
  image.
* Connect serial, power up the switch, interrupt U-boot by hitting the
  space bar, and enable the network:
  > rtk network on
* Since the GS1900-10HP is a dual-partition device, you want to keep the
  OEM firmware on the backup partition for the time being. OpenWrt can
  only boot off the first partition anyway (hardcoded in the DTS). To
  make sure we are manipulating the first partition, issue the following
  commands:
  > setsys bootpartition 0
  > savesys
* Download the image onto the device and boot from it:
  > tftpboot 0x84f00000 192.168.1.10:openwrt-realtek-generic-zyxel_gs1900-8hp-v{1,2}-initramfs-kernel.bin
  > bootm
* Once OpenWrt has booted, scp the sysupgrade image to /tmp and flash it:
  > sysupgrade /tmp//tmp/openwrt-realtek-generic-zyxel_gs1900-8hp-v{1,2}-squashfs-sysupgrade.bin

Signed-off-by: Stijn Segers <foss@volatilesystems.org>
[merge PoE case, keep device definitions separate, change all those
hashes in the commit message to something else so they don't get
removed when changing the commit ...]
Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
2021-01-09 16:19:46 +08:00
Adrian Schmutzler
007f610b1d
realtek: remove model prefix from LED label for ZyXEL GS1900
This is used as fixed status LED, so no migration is needed.

Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
2021-01-09 16:19:42 +08:00
Stijn Segers
ee6d8e6750
realtek: introduce shared DTSI for GS1900 series
The ZyXEL GS1900-8HP v1, v2 and GS1900-10HP are all built on a similar
Realtek RTL8380M platform. Create a common DTSI in preparation for
GS1900-8HP support, and switch to the macros defined in rtl838x.dtsi.

Signed-off-by: Stijn Segers <foss@volatilesystems.org>
[drop redundant includes, use &mdio directly, do not replace SFP
ports]
Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
2021-01-09 16:19:35 +08:00
Stijn Segers
d7c6801f5a
realtek: move memory node to device DTS
Move the memory out of the rtl838x.dtsi and into the device family DTSI
or device DTS if applicable. This aligns with upstream practice.

Signed-off-by: Stijn Segers <foss@volatilesystems.org>
[add missing block for dgs-1210-10p, move block below chosen node]
Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
2021-01-09 16:19:15 +08:00
AmadeusGhost
0652771a60
rtl8192du: fix build on arm64 platform 2021-01-09 16:14:11 +08:00
AmadeusGhost
277801dcfd minieap: improve output log format 2021-01-09 11:28:55 +08:00
AmadeusGhost
de1bcb45aa njitclient: switch to git source 2021-01-09 11:23:38 +08:00
AmadeusGhost
a6a5db037d scutclient: update to latest git HEAD 2021-01-09 11:20:48 +08:00
AmadeusGhost
09ba2f11a7 ngrokc: update to 1.54 2021-01-09 11:18:03 +08:00
AmadeusGhost
e7a53aaa57 rtl8192du: fix build on arm64 platform 2021-01-09 11:15:00 +08:00
John Audia
10c1005dfd kernel: bump 5.4 to 5.4.87
All modification by update_kernel.sh.

Build system: x86_64
Build-tested: ipq806x/R7800, bcm27xx/bcm2711
Run-tested: ipq806x/R7800

No dmesg regressions, everything functional

Compile-tested [*]: ath79/{generic,tiny}, ipq40xx, octeon,
                    ramips/mt7621, realtek, x86/64.
Run-tested [*]:     ramips/mt7621 (DIR-878 A1, R6800, RT-AC57U),
                    octeon (EdgeRouter Lite).

Signed-off-by: John Audia <graysky@archlinux.us>
Tested-by: Stijn Segers <foss@volatilesystems.org> [*]
2021-01-09 11:09:29 +08:00
Pawel Dembicki
5a3d288263 kernel: add hid-cp2112 driver support
This patch adds kernel module for Silicon Labs CP2112 HID USB to SMBus
Master Bridge. This is a HID device driver which registers as an i2c
adapter and gpiochip to expose these functions of the CP2112.

Signed-off-by: Pawel Dembicki <paweldembicki@gmail.com>
2021-01-09 11:06:28 +08:00
CN_SZTL
517305f9a9
qBittorrent: fix boost dependencies 2021-01-08 22:24:58 +08:00
CN_SZTL
fae6e5a577
Merge Mainline 2021-01-08 19:27:02 +08:00
xiaorouji
15d7faaf9e
luci-app-passwall: server: add xray acceptProxyProtocol option 2021-01-08 19:26:01 +08:00
Mattraks
4bfcaff4cf
luci-app-ssr-plus: bump 182-4 2021-01-08 19:15:57 +08:00
CN_SZTL
9355dd4546
luci-app-ssrserver-python: improve status check
Running `ps` via luci.exec directly will cause no output
to compare as `ps` cannot detect the size of screen, adding
`-w` to solve this.

Fixes: 0e285c3037 ("add lean's package")
Fixes: #250
2021-01-08 17:46:43 +08:00
CN_SZTL
df2d79a159
luci-app-ssr-python-pro-server: remove duplicated package 2021-01-08 16:55:59 +08:00
CN_SZTL
25642b3888
quickjs: add missing PKG_LICENSE 2021-01-08 16:32:41 +08:00
CN_SZTL
888d901ad3
ipv6helper: set ipv6 under hybrid mode by default 2021-01-08 16:22:17 +08:00